7. FISH FINDER
7-19
pulse length, and is suitable for general use. [Long] increases the detection range but
lowers the resolution (about 1/2 compared to the [Std] pulse length) (DFF3 only).
[RX Band HF (LF)]: The RX bandwidth is automatically set according to pulse length.
To decrease noise, select [Narrow]. For better resolution, select [Wide] (DFF3 only).
[Temperature Port]: Select the data source for water temperature (DFF3 only).
[MJ]: The water temperature data from the water temperature/speed sensor
[Low Frequency]: The low frequency measured water temperature
[High Frequency]: The high frequency measured water temperature
[Sounder Demo Mode]: The demonstration mode provides, with connection of the
transducer, simulated operation of the equipment, using internally generated echoes.
[Off]: Turn demo mode off.
[Shallow]: Shallow depth demonstration
[Deep]: Deep depth demonstration
[Hardware Factory Default]: Select this menu item to restore default settings for the
unit selected in [Fish Finder Source]. Not available with FCV-1150.
[Reset Default Settings]: Select this menu item to restore default settings for the
[Sounder] menu.
7.13 LCD Color Sounder FCV-1150 and NavNet
TZtouch
The FCV-1150 can be connected to your NavNet TZtouch, and some functions can
be controlled from the NavNet TZtouch. The table below shows those features that
can be controlled from the NavNet TZtouch. This feature is available with the FCV-
1150 software version 0252359-03.01 or higher.
Function
Controllable
from NavNet
Remarks
A-scope Yes
ACCU-FISH
TM
Yes
Auto gain offset No Set at FCV-1150.
Background color Yes
Bottom detection level Yes
Bottom lock range Yes
Bottom shift range No Set at FCV-1150.
Clutter No Set at FCV-1150.
Color erase Yes
Depth unit Yes
Draft No
Fish alarm Yes
Fish info Yes
Fish info size Yes
Fish level Yes
Fish size correction Yes
Fish symbol Yes
Frequency adjustment Yes
Gain Yes According to Gain/Mode setting at FCV-1150.
162


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno TZT9 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno TZT9 in the language / languages: English as an attachment in your email.

The manual is 34,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno TZT9

Furuno TZT9 User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info