2. TECHNICAL SPECIFICATIONS and APPLICATION
The output of the hydraulic reversing pump is 1.6 cu in/sec. The
volume of the steering cylinder is approximately 23.5 cu in (385
cubic centimeters). The rudder speed will be approximately 14.7
seconds hard over to hard over (HOH).
The rudder speed, hard over to hard over (HOH), is determined
by dividing the volume (cu in) of the cylinder by the output of the
pumpset (cu in/sec).
The steering cylinder is capable of approximately 1,045 lbs of thrust
based on an output of 500 psi from the pump. The force or torque
applied to the rudder through the rudder shaft is dependent of the
distance between the center of the rudder shaft and the position
of the tiller bolt.
Figure 2 CYLINDER SCHEMATIC
Distance (rudder shaft to tiller bolt): 7” = 7,315 in/lb; 8” = 8,360 in/lb;
9” = 9,405 in/lb; 10” = 10,450 in/lb. The torque required to turn the rudder
can be calculated or obtained from the vessel’s builder.
Model Number LA17-12 LA17-24
Voltage 12 VDC 24 VDC
Output/Sec 1.6 cu in/sec 1.6 cu in/sec
Average Motor Amp 4-8 3-5
Solenoid Valve Amp 1.5 AMPS .75 AMP
Weight 15 lbs (7 kgs) 15 lbs (7 kgs)
35°
PORT
35° TRUNNION CENTER
45° TRUNNION CENTER
45°
PORT
35°
PORT
45°
PORT
RUDDER SHAFT
TILLER ARM
10.5"
27.5"
8.6"
6.0"
8.5"
p02
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno LA 17 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno LA 17 in the language / languages: English as an attachment in your email.

The manual is 0,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info