3. DESCRIPTION
3.1 GENERAL
The Accu-Steer HRP05, HRP11 and HRP17 are complete
pump assemblies each consisting of a reversing gerotor gear
pump, hydraulic lock valves, suction make-up check valves,
a valve housing manifold and an electric permanent magnet
motor.
FIGURE 3.1 HYDRAULIC SCHEMATIC
Lines A and B are the output (port and starboard) lines, which
are connected to steering lines on the vessel. Line T is the tank
suction make-up or return line. These lines are clearly marked
on the valve housing. Do not connect the output lines to the
tank (T) port.
The HRP (Hydraulic Reversing Pumpset) operates as follows:
 t As the motor (1) rotates CCW, oil from the gear pump (2) is
pumped towards output “A”.
 t This oil passes through the check valve (5) and goes to the
line output (7).
 t The pressure at output “A” ensures the check valve (3)
stays closed and manually opens check valve (6).
“A”
2
1
43
8
5
79
6
DC
MOTOR
“B”
p03
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno HRP17 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno HRP17 in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info