 t The shaft seal is accomplished using a rubber shaft seal
rated at 50 psi. This shaft seal is connected to the tank/re-
turn line pump chamber. If this tank port is connected to a
steering line or is over pressurized, it may cause this seal to
fail.
See the installation instructions for more details.
3.4 VALVE BLOCK and VALVES
A list of features:
 t The valve block is an aluminum block, precision machined
to house the valves, direct the oil and serve as the endplate
for the gear pump. The pump end plate is referenced to the
valve block with locator pins to ensure the proper align-
ment.
 t The suction make-up valves are located between the return
line port and the pump output internal ports. These allow
the pump to “breathe” properly in the event of air from the
steering lines entering the pumpset.
 t The output check valves are part of what is called a lock-
valve assembly. The lockvalve assembly consists of two
output check valves and a lockvalve spool. In the non-
running position the spring operated check valves remain
closed, isolating the pump from the steering system. The
spring action of the check valves holds the lockvalve spool
in the mid-closed position.
 t The end plate houses the pump shaft guide and aligns the
pump.
4. INSTALLATION
4.1 MECHANICAL
The pumpset should be placed on a horizontal shelf or bracket
with a solid foundation. The pump can be bolted or screwed
down with the motor foot bracket. The foot bracket is tted
with anti-vibration mounts to maintain the quiet operation of
the pumpset. The pumpset should be close to and below the
steering lines for ease of connections and bleeding.
4.2 HYDRAULIC
Before connection to the hydraulic lines, ensure all hydraulic
lines in the steering system are clean and free of contaminating
particles, which could enter the pump and cause it to fail.
p05
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno HRP05 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno HRP05 in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info