FURUNO
GS-100
SP - 2 E7279S01D
4 DISPLAY UNIT (DS-600, OPTION)
4.1 Screen 8.4-inch, Color LCD, 640 x 480 dot (VGA)
4.2 Brilliance 0.2 to 500 cd/m
2
4.3 View angle Up/down/left/right: 75° or more (color is not considered)
4.4 Dimmer External dimmer control available
4.5 Backlight life 30,000 hrs approx. (+55°C)
5 INTERFACE
5.1 Number of ports
Serial I/O: 3 ports, O: 1 port
Ethernet 1 port, 100base-TX
USB 1 port for maintenance
CAN (spare) 1 port
5.2 Data format IEC61162-1/2 (NMEA0183 V1.5/2.0/4.0), IEC61162-450
5.3 Data sentence
Input ACK, ACM, ACN, CUR, DPT, HBT, HDG, HDT*, MWV, THS, VBW,
VDR
Output ALC, ALF, ALR, HBT, HDT*, HRM, POS, ROT, THS, VBW, VLW,
VTG, ZDA
5.4 Output proprietary sentence
PFEC GPatt, GPhve, IIalr, IIals, pidat, pireq, rminf
5.5 Ethernet 100Base-TX, RJ45 connector (waterproof)
IEC61162-450 transmission group
IN: MISC, SATD, NAVD
OUT: Arbitrary (default: NAVD)
Other Network Function (ONF) group of IEC61162-450
SNTP, HTTP, Furuno Management Protocol (FMP)
Sentences
IN: ACK, ACM, ACN, CUR, DPT, HBT, HDG, HDT*, MWV, THS, VBW,
VDR
OUT: ALC, ALF, ALR, HBT, HDT*, HRM, POS, ROT, THS, VBW, VLW,
VTG, ZDA
Sentence type
CRP (Command-response pair) ACK, ACN, ALC, ALR, ALF, POS
SBM (Sensor broadcast message)
HBT, HDG, HDT, ROT, THS, VBW, VDR, VLW, VTG, ZDA
5.6 Contact closure (optional IF-2503 required)
Dead reckoning, IF-2503 power fail
*: Not used by SOLAS ships.
6 POWER SUPPLY
6.1 Junction box 24 VDC: 0.6 A (supplied to display unit and antenna unit)
6.2 Rectifier (option)
PR-240 100-115/200-230 VAC, 1 phase, 50/60Hz, 24VDC for back-up
PR-62 100/110/115/220/230 VAC, 1 phase, 50/60Hz