-2.1-
2 OPERATION OF AUTOMATIC TRACKING AID (ATA) ARP-17
2.1 Introduction
The FR-1500 MARK-3 series radar can accommodate an optional ATA (Automatic Tracking Aid)
module complying with IMO MSC.64(67) Annex 4 and IEC 60872-2. With the optional ATA circuit
board (ARP -17) fitted in the display unit, the radar will automatically acquire 10 targets coming into
the acquisition area. Once a target is acquired automatically or manually it is automatically tracked
within 0.2 to 32 nm, whether inside or outside the acquisition area.
Principal specifications
Auto tracking range: 0.1 - 32 nm, irrespective of range scale and acquisition range
Vector length: 0.5 sec., 1, 2, 3, 6, 12, 15, 30 min.
Orientation: True velocity or relative velocity
Stabilization: Sea or Ground stabilization
Motion trend: Displayed within 20 scans, full accuracy within 60 scans after acquisition.
Past positions: 10 past positions at intervals of 30 sec, 1, 2, 3 or 6 min.
Alarms: Visual and audible alarms against targets violating CPA/TCPA limits, lost
targets, targets crossing guard zone, system failure and target full status.
ATA Menu tree
MENU key --------------- 1. VIDEO PLOT/AIS* Requires RP-17 or RP-180. AIS not shown on RP-17
------- 2. TGT TRAIL
------- 3. TGT ALARM
------- 4. WATCH TIME
------- 5. ECHO SIG
------- 6. FUNC
------- 7. PLOT-------------------1. MARK DISP (OFF/ON)
------- 8. MARK ----- 2. ERASE
------- 9. BRILL ----- 3. VECT REF (REL/TRUE)
------- 0. OTHERS ----- 4. VECT TIME (30SEC/1/3/6/15/30MIN)
----- 5. CPA SET (OFF/0.5/1/1.5/2/3/4/5/6NM)
----- 6. TCPA SET (30SEC/1/2/3/4/5/6/12/15NM)
----- 7. TRACK (ON/OFF)
----- 8. AUDIO ALARM (OFF/ON)
----- 9. INTVAL (30SEC/1/2/3/6 min)
----- 0. ----------------1.
-----2. AUTO ACQ (OFF/ON/SET)
-----3. GUARD ZONE (OFF/ON/SET)
-----4. TRACK TEST
-----5. LAND DISCRIM (0/1/2/3/4)
-----6. TTM (OFF/REL/TRUE)
-----7. VECTOR START (1 min/20 scans)
-----8. REF TGT VECTOR (OFF/ON)
-----9. TARGET BASED SPEED
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno FR1510 MARK-3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno FR1510 MARK-3 in the language / languages: English as an attachment in your email.

The manual is 1,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno FR1510 MARK-3

Furuno FR1510 MARK-3 Installation Guide - English - 75 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info