ENVIRONMENTAL CONDITIONS
1. Ambient temperature (Complies with IEC 60945)
Display unit: -15 to +55°C
Antenna unit: -25 to +70°C (Storage)
2. Relative humidity: 93% at 40°C
EQUIPMENT LIST
Standard
.1 Display unit RDP-119 (AC or DC)
.2 Scanner unit RSB-0074 (24 rpm), -0075 (42 rpm) with
RF transceiver unit RTR-067 (6 kW), -062 (12 kW),
-063 (25 kW)
.3 Antenna radiator
XN-12AF (4 ft), -20AF (6.5 ft), -24AF (8 ft)
.4 Antenna cable 15/20/25/30m (Specify)
COATING COLOR
Display Unit: Panel: N3.0 (Dark grey)
Cover: 2.5GY5/1.5 (Light grey)
Antenna Unit: N9.5 (White)
Option
.1 Power cable CVV-S8x2C 15 m (for DC set)
.2
Stepdown transformer RU-1803 (440 V, 1ø)
.3 Rectifier RU-1746B-2 (115/230 V to 24 VDC)
.4 Rectifier RU-3424 (115/230 V to 24 VDC for 25 kW, 42
rpm)
.5 42 rpm scanner motor
.6 ARPA board ARP-17
.7 Video plotter board RP-17 or RP-180 (Mandatory on
IMO-type)
.8 ROM card (for digital charts), RAM card (for custom
data) for RP-17 expanded radar map
.9 Sub display FMD-8001 (R-type)
Electromagnetic radiofrequency radiation
MODEL RADIATOR TYPE Distance to 100 W/cm
2
Distance to 10 W/cm
2
RF power density on
antenna aperture
FR-1505 M3 (X, 6 kW) XN12AF (4’) none 2.1 m 75 W/cm
2
XN20AF (6.5’)
FR-1510 M3 (X, 12 kW) XN12AF (4’) 1.1 m worst case 10.0 m worst case 200 W/cm
2
worst case
XN20AF (6.5’)
FR-1525 M3 (X, 25 kW) XN20AF (6.5’) 1.1 m worst case 10.0 m worst case 200 W/cm
2
worst case
Category of Equipment Units
Equipment for Protected Area Equipment for Exposed Area
Display unit
Power supply unit
Interswitch unit
Antenna unit (Scanner unit, RF Transceiver unit)
Performance monitor
Compass safe distance
Equipment unit Standard compass Steering compass Remarks
Display unit RDP-119 0.80 (0.50) m 0.50 (0.30) m
Antenna unit RTR-067 (6 kW) 1.40 (0.85) m 0.70 (0.45) m For all radiators
Antenna unit RTR-062 (12 kW) 1.70 (1.05) m 0.90 (0.55) m For all radiators
Antenna unit RTR-063 (25 kW) 2.10 (1.30) m 1.20 (0.75) m For all radiators
RF Transceiver unit
Performance monitor PM-30 (X-band) 0.4 m 0.3 m
Measurements by the BSH, Germany, Cert Nr. 287/2. Figures in ( ) apply to the coastal boats
under German Regulations.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno FR1510 MARK-3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno FR1510 MARK-3 in the language / languages: English as an attachment in your email.

The manual is 1,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno FR1510 MARK-3

Furuno FR1510 MARK-3 Installation Guide - English - 75 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info