689490
18
Zoom out
Zoom in
Previous page
1/75
Next page
2-2
Figure 2-2 Scanner unit, front view, cover removed
5. Pass the signal cable through the cable entry hole in the scanner unit mounting
platform. Trim the cable so about 80 cm of it protrudes past the cable gland.
6. Slide the clamping ring, washer, rubber gasket and washer onto the cable in
that order.
7. Fabricate the signal cable as shown on page 2-4.
8. Referring to Figure 2-3, pass the outer and inner shields between the signal
cable and the clamping ring. Fasten the cable gland.
Figure 2-3 Passing cable shields between cable and clamping ring
9. Connect the signal cable to the terminal board RTB801 in the scanner unit by
referring to the interconnection diagram. Leave “slack” in the coaxial wire to
prevent breakage.
10.Bind cores of cables with cable ties.
11.Set the transceiver unit to the scanner unit, push it in until it stops, and then
tighten fixing bolts (4 pcs.). Connect plugs P611, P801 and P821. Twist the
shields of the signal cable together and fasten them to the ground terminal on
the transceiver module.
12.If the scanner is mounted 2˚ or more left of ship’s bow, adjust the position of
S901 so it becomes “on” (contact between #1 and #2 on pcb MP-3795). To
access S901, open the bow side cover; S901 is above the drive gear.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno FR1505 MARK-3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno FR1505 MARK-3 in the language / languages: English as an attachment in your email.

The manual is 2,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno FR1505 MARK-3

Furuno FR1505 MARK-3 User Manual - English - 125 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info