23252
5
Zoom out
Zoom in
Previous page
1/8
Next page
Server FI-3005
The server is the heart of the FI-30 instrumentation network. It is also
an intelligent junction box for the transducers and sensors. Furuno
NavNet equipment can also be connected through the NMEA digital
interface. (NMEA is a standard on the server.)
Enclosure: Splashproof
Power supply: 12 VDC, 27 mA
S/T Sensor FI-3002
The paddlewheel speed sensor molded in
the unique plastic housing is fitted under
the hull. Retractable through hull mount for
easy replacement or cleaning. Dummy
plug included.
Depth Transducer FI-3001
The depth sounding transducer is fitted
under the hull. The display unit permits
settings of measurement below water
surface or keel.
Frequency: 200 kHz
Wind Sensor FI-3003
Sensitive and stable sensor provides accurate
wind speed and direction for the network. Easy,
snap-in attachment for mast mounting included.
Accuracy: Angle ± 0.5%
Speed ± 0.5 m/s (kt, bf)
Power supply: 12 VDC, 20 mA
Cable: 25 m
Fluxgate Compass FI-3004
Gimbaled and liquid damped for superb stability in rough
seas. Sensitivity and accuracy are proven over years of
installation and through continued technical improvement.
The sensor is automatically corrected for deviation in the
Multi Control.
Accuracy: ± 1.5%
Sensitivity: ± 0.1°
Pitch and roll: 45°
Power supply: 12 VDC, 25 mA
Cable: 8 m
Integrated Heading Sensor
PG-500
An inexpensive electromaganetic compass
provides a highly accurate and stable readout of
the ship's heading thanks to the sophisticated
structure by three-axis magnetometer, incliometer
and integral vibrating gyrosensor.
Accuracy: ± 1.5%
Sensitivity: ± 0.1°
Pitch and roll: 35°
Power supply: 12-24 VDC
Magnetic variation: Automatic compensation
(Appropriate GPS
Navigator required.)
Magnetic deviation: Automatic re-calibration
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno FI30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno FI30 in the language / languages: English as an attachment in your email.

The manual is 1,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info