522205
33
Zoom out
Zoom in
Previous page
1/62
Next page
5. INSTALLATION
23
5.3 Wiring
5.3.1 Standalone configuration
For standalone configuration the junction box is not necessary; connect
the instrument directly to the power supply.
Note: Turn on the display unit’s terminal resistor. For the procedure, see
page 33 (FI-501/502/505 or page 35 (FI-506)
Using the terminal box
As shown in the figure above, the display unit is connected to the wind
transducer with the cable assy. FI-50-SENSOR-30/50. However, if the
connector of the cable cannot be passed through the mast (because its
diameter is too small), use the Terminal Box to make the connection.
Wire it as shown on the next page. The box is not waterproof; locate it
out of areas subject to rain or water splash. The length of the cable be-
tween the FI-5001 and display units is maximum 50 m.
1. Cut the connector from the FI-50-SENSOR-30/50 cable and pass the
cable thru the mast.
2. Fabricate the above-mentioned cables as shown below.
Cable Assy. FI-50-SENSOR-30/50
(30 m or 50 m)
FI-50-DROP
Cable (6 m)
Display Unit
FI-501/502/505/506
Wind Transducer
FI-5001*
Red
Black
+
12 VDC
* Omit for FI-505/506.
40
5
Twist shield.
TERMINAL
40
5
Twist shield.
FI-50-SENSOR Cable
(from wind transducer)
FI-50-SENSOR Cable
(from display unit)
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno FI-502 CH WIND ANGLE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno FI-502 CH WIND ANGLE in the language / languages: English as an attachment in your email.

The manual is 2,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info