28266
16
Zoom out
Zoom in
Previous page
1/239
Next page
1. OPERATIONAL OVERVIEW
1-5
1.3 Turning the Unit On/Off
Press the POWER/BRILL key to turn the unit on. A beep sounds and then the equipment
shows the startup NavNet screen (about 20 seconds), the product information screen,
startup test results and chart usage disclaimer. During this period the equipment is
inoperative. The startup test checks the ROM, RAM, internal battery and backup data for
proper operation, displaying the results for each as OK or NG (No Good). If NG appears an
appropriate message appears on the screen. For any NG, try to press any key to go to the
chart disclaimer screen, then perform the diagnostic test as shown in the paragraph “8.8
Diagnostics.
For start up with the radar display, the magnetron takes from one minute and thirty
seconds to three minutes (depending on radar model) to warm up before the radar can be
operated. The time remaining for warming up of the magnetron is counted down at the
center of the display.
You may press any key at the chart disclaimer screen to show the last-used display, or wait
several seconds to let the equipment do it for you.
To turn the unit off, press and hold down the POWER/BRILL key until the screen goes off
(approx. 3 sec.). To protect the LCD attach the hard cover. Note that the network sounder
will be turned off approx. three minutes after turning off the power. This is due to the
system’s electrical characteristics.
Note: The first time you turn on the power (or any time the power is applied after a memory
reset), you are asked if you want to start the simulation mode, which provides simulated
operation of the equipment after the installation mode selection. Push the ENTER knob to
start the simulation mode, or press the CLEAR key to start normal operation. For further
details about the simulation mode, see the paragraph “1.10 Simulation Display.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno 1834C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno 1834C in the language / languages: English as an attachment in your email.

The manual is 5,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno 1834C

Furuno 1834C User Manual - Spanish - 241 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info