522147
19
Zoom out
Zoom in
Previous page
1/252
Next page
1. OPERATIONAL OVERVIEW
1-5
1.3 Turning the Unit On/Off
Press the [POWER/TX] key on the control unit to turn on the power. The
POWER lamp on the processor unit lights. A beep sounds and the equipment
proceeds in the sequence shown below, displaying product information, startup
test results and the chart usage disclaimer. The startup test checks the ROM,
RAM, internal battery and backup data for proper operation, displaying the
results for each as OK or NG (No Good). If NG appears try to press any key to
go to the chart disclaimer screen, then perform the diagnostic test as shown in
the paragraph “7.5 Diagnostics.”
RADAR PLOTTER
*
STATION NAME:
RADAR#
FURUNO ELECTRIC CO., LTD.
CHARTS AVAILABLE
LICENSE NO.
STARTUP TEST
ROM OK
RAM OK
BACKUP DATA OK
INTERNAL BATTERY OK
Î
Î
Product information Startup test Chart disclaimer
Host Name
Chart List
NONATIONALHYDROGRAPHIC
OFFICEHASVERIFIEDTHE
INFORMATIONINTHIS
COASTLINEDATACARDANDNONE
ACCEPTLIABILITYFORTHE
ACCURACYOFREPRODUCTIONOR
ANYMODIFICATIONSMADE
THEREAFTER.THISPRODUCTWITH
THISCOASTLINEDATACARD
DOESNOTREPLACETHE
REQUIREMENTTOUSETHE
APPROPRIATEPRODUCTSFOR
NAVIGATIONACCORDINGTO
NATIONALANDINTERNATIONAL
REGULATIONS.
PROGRAMNo.1950011XXX**
**=Programversionno.for
FURUNO/NAVIONICS
model.1950010XXXforC-MAPmodel.
XXX=programversionno.
* = "GD-1900C-BB Plotter" for GD-1900C-BB
#= Name determined at installation.
Startup sequence
For start up with the radar display, the magnetron takes from one minute to
two minutes and thirty seconds (depending or radar model) to warm up before
the radar can be operated. The time remaining for warming up the magnetron is
counted down at the center of the display.
You may press any key at the chart disclaimer screen to show the last-used
display, or wait several seconds to let the equipment do it for you.
To turn the unit off, press and hold down the [POWER/TX] key until the screen
goes dark (approx. 3 sec.). Note that if the network sounder is connected, it will
be turned off approx. three minutes after turning off the power.
Note: The first time you turn on the power (or any time the power is applied after
a memory reset), you are asked if you want to start the simulation mode,
which provides simulated operation of the equipment. Push the [ENTER]
knob to start the simulation mode, or press the [CLEAR] key to start
normal operation. For further details about the simulation mode, see the
paragraph “1.10 Simulation Display.”
offered by Busse-Yachtshop.de
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno 1823C-BB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno 1823C-BB in the language / languages: English as an attachment in your email.

The manual is 3,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info