SP - 3
4.6 Output Data
Alarm signal 12 VDC, 100 mA or less
NMEA 0183 Ver1.5 GGA, GLL, RMA, RMC, GTD, VTG, ZDA (GPS data required)
RMB, WPL, BWC or BWR, APB, AAM, BOD, XTE, VHW, MTW,
DPT or DBT, HDT, HDG, MWV, ZTG
TLL (L/L, Heading data required), TTM (ARPA required)
5 PLOTTER FUNCTION
5.1 Projection Mercator
5.2 Usable Area 85 latitude or below
5.3 Effective Area 133.4 x 97.3 mm
5.4 Display pixels 480 x 640 dots
5.5 Position Indication Latitude/longitude, Loran C LOP, DECCA LOP or MGRS
5.6 Effective Projection Area 0.125 nm to 2,048 nm (at equatorial area)
5.7 Track Display Plot interval: by time (1 sec. to 99 min. 99 sec.) or
by distance (0 to 99.99 nm)
5.8 Track Colors Red, yellow, green purple, light-blue, blue, white
5.9 Memory Capacity Track/mark: 8000 points, Waypoint: 999 points
5.10 Storage Capacity Simple route: 200 routes with 35 waypoints each
5.11 MOB 1 point
5.12 Quick Routes 1 course with 35 waypoints max.
5.13 Electronic Chart SD Card: NAVIONICS Gold Chart card, or
C-MAP NT MAX chart card
5.14 Alarms Arrival and Anchor watch, Cross track error and proximity
alarms, Ship’s speed in and out alarms, Water temperature,
Trip alarm, Fish alarm, Bottom alarm (ETR required), Grounding
alarm (C-MAP only)
6 POWER SUPPLY
6.1 Rated Voltage/Current
M1724C 12-24 VDC: 5.9-2.8 A
M1734C 12-24 VDC: 5.6-2.7 A
6.2 Rectifier (option) PR-62: 100/110/115/220/230 VAC, 1 phase, 50/60 Hz