3.4 Adjustments for
Technicians
1) Magnetron heater voltage
Magnetron heater voltage is formed at the MD
Board of the antenna unit and preadjusted at
the factory for use with any length of signal
cable. Therefore no adjustment is required.
However, verify heater voltage as follows:
CAUTION
Lift the radome cover slowly.
The antenna radiator may be caught by
the screw holes in the radome cover.
If you feel the radiator is caught by the
screw holes, lower the cover, turn it a
few degree and then lift it again.
Screw holes
(4 places)
Note:
Turn the power on when measuring
magnetron heater voltage.
1. Dismount the shield plate.
MD board under
the shield plate
Figure 27 MD board
2. Turn on the power. Do not transmit the
radar.
3. Connect a multimeter, set to 10 V DC
range, between #6(+) and #4(-) of test
point TP804 on the MD Board in the
antenna unit.
4. Confirm that the multimeter shows 8.0 V
±0.1 V. If it does not, adjust potentiometer
VR801 on the MD Board.
TP804
VR851
VR801
Figure 28 Antenna unit, inside view
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furuno 1712 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furuno 1712 in the language / languages: English as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Furuno 1712

Furuno 1712 User Manual - English - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info