587425
13
Zoom out
Zoom in
Previous page
1/15
Next page
12
OPERATION DETAILS
Temperature and Humidity Range
Permissible range of temprature and humidity are as follows:
Operation and Performance
* Heating Performance
This air conditioner uses a heat pump which absorbs heat
from outside air and brings it indoors. As a result, its heat-
ing performance is reduced as the temperature of out-
side air drops. If you find that insufficient room heat is
produced, we recommend that you use the air conditioner
together with other heating appliances.
Heat-pump type air conditioners use warm-air
recirculation to warm your entire room. As a result, some
time will be required after starting operation until your
entire room becomes warm.
*
Microcomputer-controlled Automatic Defrosting
When the outside temperature is low and the humidity high,
frost will collect on the outside unit, reducing heater effi-
ciency. When this happens, the computer will automatically
start the defrost cycle. During the defrost cycle, the indoor
fan will shutdown and DEFROST will be displayed on the
remote controller. It will take anywhere from 4 to 15 min-
utes before the air conditioner starts up again.
*
When Indoor and Outdoor Temperatures are High
When both indoor and outdoor temperatures are high dur-
ing use of the heating mode, the outdoor units fan may stop
at times.
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Please read and understand the following details regarding this air conditioner.
Low Ambient Cooling
When the outdoor temperature drops, the outdoor units fans
may switch to Low Speed, or one of the fans may stop inter-
mittently.
Should the power supply to the air conditioner be inter-
rupted by a power failure, the air conditioner will restart
automatically in the previously selected mode once the
power is restored.
AUTO Restart
In Event of Power Interruption
Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
turn off the circuit breaker turn it on again and then use
the remote controller to resume operation.
Cooling Mode
About 0 to 46 °C
About 0 to 46 °C
About 18 °C to 30 °C
About 80 % or less
If the unit is used for long pe-
riods under high-humidity
conditions, condensation
may form on the surface of
the indoor unit, and drip onto
the floor or other objects un-
derneath.
*Heating Mode
About 10 to 21 °C
About below 30 °C
Outdoor temperature
Indoor temperature
Indoor humidity
COOLING MODEL
HEAT & COOL MODEL
(Reverse Cycle)
If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling mode, if the unit is used under conditions of lower tem-
peratures than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in
ordinary dwellings.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fujitsu AOT90EP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fujitsu AOT90EP in the language / languages: English as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info