453983
11
Zoom out
Zoom in
Previous page
1/12
Next page
OCCURRENCE SOLUTION
Wall plug disconnected. Push plug firmly into wall outlet.
Plug Current Device Tripped. Press the RESET button.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
Control is OFF. Turn Control ON and set to desired setting.
Air conditioner will not operate.
Air conditioner cooling, but room
is too warm - NO ice forming on
cooling coil behind decorative
front.
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is set too high. Set temperature to a lower setting.
Air directional louvers positioned improperly. Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,
floor and furniture.
Air conditioner turns on and off
rapidly.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils
more frequently.
Before You Call
Air conditioner cooling, but room
is too warm - ice forming
on cooling coil behind decorative
front
Outdoor temperature below 60 F (16 C). To defrost the coil, set FAN ONLY mode.
OO
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY
mode.
Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then,
set temperature to a higher setting.
11
Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above
60°F (16°C).
Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.
Air from unit does not feel cold
enough.
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to
restart when set in the COOL mode.
Reset to a lower temperature.
Noise when unit is cooling.
Air movement sound. This is normal. If too loud, set to lower FAN setting.
2009 Electrolux Home Products, Inc. All rights reserved.
Water dripping INSIDE when
unit is cooling.
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to
installation instructions or check with installer.
Water dripping OUTSIDE when
unit is cooling.
Unit removing large quantity of moisture from humid room. This is normal during excessively humid
days.
Window vibration - poor installation. Refer to installation instructions or check with installer.
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not
the result of defective workmanship or materials in this appliance.
If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service.
Remote Sensing Deactivating
Prematurely (some models).
Remote control not located within range. Place remote control within 20 feet & 120° radius of the
front of the unit
Room too cold.
Set temperature too low. lncrease set temperature.
Remote control signal obstructed. Remove obstruction.
Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote
control or deactivate remote sensing.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frigidaire FRA083AT7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frigidaire FRA083AT7 in the language / languages: English as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info