4
A ‘beep’ sound is heard in learn mode…
¬● The push you are programming has already been learnt by the chime.
¬● If you want to change the icon associated with the push, use the un-learn procedure, then
programme the push again.
Two ‘beep’ sounds are heard after the normal chime sound…
¬● This indicates a low battery in the bell push that activated the chime. Fit a new battery, type CR2032.
When the bell push is operated, the amber confidence light does not turn on, or is only
on for a short time…
¬● In normal operation, the amber light will turn on for 1 second. When the battery is weak,
the light will only turn on for a short time. Fit a new battery, type CR2032.
The chime does not work…
● Check that the batteries are the correct type. Only use alkaline batteries.
● Check that the batteries are fitted correctly.
● The chime could be out of range of the bell push. Try the chime in a different location.
● The chime might not have learnt the identity of the bell push. Follow the programming procedure.
The chime does not sound…
● Check that the volume control is not at the minimum setting.
Range is reduced…
● Metal structures, including uPVC door frames can reduce the range of the product.
Avoid mounting the push or chime on or near metal structures.
● Other equipment can cause radio interference that affects your chime.
● Walls and ceilings will reduce the range.
● Weak batteries will reduce range. Replace every 12 –18 months. In cold conditions (below 5ºC),
batteries may need to be replaced more often.
Push does not work with my older Libra equipment …
● Libra + is not compatible with the earlier Libra system.
● Only use accessories marked Libra +.
Troubleshooting