PFS
20
EN
Overheat protection
The fan convector is equipped with overheat
protection. The overheat protection resets by
Packaging
Packaging materials are chosen with
consideration to the environment and are
therefore recyclable.
Handling of product at end of working life
This product may contain substances
necessary for the functionality of the product
but potentially dangerous for the environment.
The product should not be disposed of mixed
with general household waste but delivered to
a designated collection point for environmental
recycling. Please contact the local authority
for further details of your nearest designated
collection point.
Safety
For all installations of electrically heated
products a residual current circuit breaker
300 mA for fire protection should be used.
Keep the areas around the air intake
and exhaust grilles free from possible
obstructions!
The unit must not be fully or partially
covered as overheating can result in a fire
risk!
This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning
use of the appliance in a safe way and
understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made by
children without supervision.
Service, repairs and maintenance
For all service, repair and maintenance first
carry out the following:
1. Disconnect the power supply.
2. The front is opened by removing the screws
on the plastic ends (2x), pull the front at
the bottom and then lift it up. (Fig. 8)
3. Reinstall the front.
Maintenance
In all electrical heating appliances, small
clicks can occur due to movement when the
material expands and contracts with changes
in temperature.
Since fan motors and other components are
maintenance free, no maintenance other than
cleaning is necessary. The level of cleaning
can vary depending on local conditions.
Undertake cleaning at least twice a year. Inlet
and exhaust grilles, fans and elements can be
vacuum cleaned or wiped using a damp cloth.
Use a brush when vacuuming to prevent
damaging sensitive parts. Avoid the use of
strong alkaline or acidic cleaning agents.
turning off the unit during 10 minutes.
Replacing the fan motor
1. Disconnect the power supply.
2. The front is opened by removing the screws
on the plastic ends (2x), pull the front at
the bottom and then lift it up. (Fig. 8)
3. Disconnect the cables to the motor.
4. Remove the screws securing the motor and
lift it out.
5. Install the new motor as above in reverse
order.
6. Reinstall the front.
Switching surface temperature 60 / 90 °C
On delivery, max. surface temperature is
set to 90 °C. To select the lower surface
temperature - max 60 °C, remove the jumper
on the circuit board placed below the display
inside the convector.
1. Disconnect the power supply.
2. The front is opened by removing the screws
on the plastic ends (2x), pull the front at
the bottom and then lift it up. (Fig. 8)
3. Remove the jumper. Fig. 9.
4. Reinstall the front.
A surface temperature of 60 °C can at some
conditions result in a power reduction, to
keep the temperature low.
Start-up (E)
When the unit is used for the first time or
after a long period of non-use, smoke or an
odour may result from dust or dirt which has
collected on the element. This is completely
normal and disappears after a short time.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frico PFSE17 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frico PFSE17 in the language / languages: English as an attachment in your email.

The manual is 0.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info