787188
10
Zoom out
Zoom in
Previous page
1/12
Next page
Infracalm
10
EN
Installation and operating instructions
Positioning
The heaters must be placed so that they
enclose the area to be heated, see fig. The
normal assembly height is 2–2,5 metres
above the ground/floor. A rule of thumb for
infrared heaters equipped with metal tubular
elements is that 750–1000 W/m² increases
the experienced temperature by about 10°C.
The output demand can be reduced if the
area to be heated is protected. If the area
only has a roof, at least 1000 W/m² should be
installed. 750 W/m² is sufficient if the area has
three walls. For enclosed areas, the output
demand must be calculated. A green house for
example requires 250-300 W/m². Optimum
comfort is achieved if the heat is distributed
from at least two directions.
Mounting
Infracalm is installed horizontally on the
ceiling or on the wall with the supplied
adjustable mounting brackets. The angle
of the heater can be adjusted for optimum
comfort. The standard brackets cannot be
used for angled installation on the ceiling,
because the distance then becomes less than
the minimum distance. Infracalm can also be
suspended by wire. For minimum distance,
see diagrams on introductory pages.
The distance between the brackets is
adjustable and can be chosen according to
General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used
in the manner intended and in accordance
with the instructions.
Application
Infracalm provides year round comfort
to wind protected outdoor areas such as
balconies, patios and restaurant terraces.
Infracalm is also suitable for temporary
heating, e.g. in premises that are used
occasionally, or for spot heating.
Protection class: IP24.
Control
A stepless output control and a timer are
available for outdoor use.
When using this product as a local space
heater according to Ecodesign Regulation
(EU) 2015/1188, it must be supplemented with
one of the following approved controls.
TAP16R, electronic thermostat that includes:
- Electronic room temperature control plus
week timer
- Room temperature control with open
window detection
- Adaptive start control
TAP16R and SKG30, black bulb sensor that
include:
- Electronic room temperature control plus
week timer
- Room temperature control with open
window detection
- Adaptive start control
Connection
Infracalm is intended for permanent
installation. The installation, which should
be preceded by an omnipolar switch with a
contact separation of at least 3 mm, should
only be wired by a competent electrician and
in accordance with the latest edition of IEE
wiring regulations.
The terminal block, which also enables
connection to other heaters, is situated on the
same end of the heater as the data label. The
supplied cable gland are to be mounted in the
knock-outs. Please note that the inlet must be
tight. See wiring diagrams.
the most appropriate place for installation.
The mounting brackets enable wall mounting
in three different angles; parallel to the wall,
18° or 36° angle. For ceiling mounting the
bracket must always be mounted with 0° to
the ceiling. See the introduction pages.
Choose the desired angle and fasten the
bracket onto wall or ceiling. The holes are
Ø5 mm, c-c distance is 25 mm.
Fasten the heaters, snap into the brackets
and secure it by tightening the securing
screws (104 mm long) and the domed nuts
(spanner width 7 mm).
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frico Infracalm at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frico Infracalm in the language / languages: English as an attachment in your email.

The manual is 0.78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Frico Infracalm

Frico Infracalm User Manual - German - 13 pages

Frico Infracalm User Manual - Dutch - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info