IH
7
EN
Installation and operating instructions
General Instructions
Read these instructions carefully prior to
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid should the product
be used in the manner intended and in
accordance with the instructions.
Application
The infrared heater IH is powerful with a
high filament temperature of 2200 °C and
is the perfect choice for exposed outdoor
environments where design is important. IH
is available in two different designs. IHW gives
a comfortable heat in the occupied zone from
close range and also wider heat distribution.
IHF has more direct heat distribution and is
designed to be installed higher up.
Protection class: IP44.
Positioning
The heaters must be placed so that they
cover the area to be heated, see fig. 1. The
normal mounting height is 2–3 metres above
the ground/floor. A rule of thumb for infrared
heaters is that 600–800 W/m² increases the
experienced temperature by about 10 °C. The
output demand can be reduced if the area to
be heated is protected. If the area only has a
roof, at least 800 W/m² should be installed.
600 W/m² is sufficient if the area has three
walls. For enclosed areas, the output demand
must be calculated. Optimum comfort is
achieved if the heat is distributed from at
least two directions.
IHW provides wide heat distribution (60°),
recommended installation height 1.8 – 2.5 m.
IHF provides directed heat distribution (40°),
recommended installation height 2.3 – 3.5 m.
Start-up
When the unit is used for the first time or
after a long period of non-use, smoke or an
odour may result from dust or dirt which has
collected on the element. This is completely
normal and disappears after a short time.
Mounting
IH is installed horizontally on walls with
supplied bracket. The heater can be angled
up to 45°. The heater can also be mounted
on e.g. a parasol or a post, a suitable U-bolt
(not included) is used for this together with
the supplied console. For ceiling installation
use ceiling bracket IHE (accessory). For other
mounting alternatives, see accessories.
For minimum distance, see diagrams on
introductory pages.
1. Secure the bracket on the wall with at least
2 screws. If the keyhole slots are used, an
addition screw is needed to fix the bracket.
See the introduction pages.
2. Remove the screws fixed to the unit's back
on delivery.
3. Hook the unit on the bracket.
4. Lock in position with the screws.
Connection
IH is equipped with a 0.9 metre cord with
plug for connection to an earthed outlet
socket.
The connection cord must not rest against
the unit as the surface becomes hot or can
be hit by thermal radiation. Contact an
electrician if the cord needs to be changed.
Note that due to the high temperatures in the
heater, a cord of the type H05 RN-F 3G1 mm²
or the like should be used.
As the halogen lamp has a high starting
current the wall socket should be fuse
protected by a slow burn fuse.
In the event of uncertainty contact an
electrician.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frico IHW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frico IHW in the language / languages: English as an attachment in your email.

The manual is 0.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Frico IHW

Frico IHW User Manual - German - 13 pages

Frico IHW User Manual - Dutch - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info