628407
16
Zoom out
Zoom in
Previous page
1/48
Next page
16
8.1.1 Lines
All the control unit lines can be configured independently.
- Instantaneous line: The anti-intrusion input line is active when the control unit is activated,
even during the input and output time. An alarm activates the buzzer and the alarm LEDs on
the keypads. The alarm is shown on the display.
Only the outputs and the phone channels associated with this line are activated.
Standard: setting for all traditional detectors such as volumetric sensors or perimeter
contacts.
Vibration: The CE2N-416 control unit can directly connect to a vibration contact at the line
input without using any other additional analysis card.
Def. Load. V=yes X=no: all the default parameters of this line type will be loaded.
Sensitivity: value expressed in milliseconds to establish how sensitive the line must
be in reception.
Impulses: the number of necessary impulses that the line must receive is set before
the control unit generates an alarm.
Int. time: the setting of the “integration time” defines the time by which the control unit must
count the “impulse number” set in the item of the previous menu.
Wire: The CE2N-416 control unit can connect a roller wire contact directly to the line input
without using any additional analysis card.
Def. Load. V=yes X=no: this procedure allows you to load the default parameters set for
this type of line.
Impulses: the number of necessary impulses that the line must receive is set before the
control unit generates an alarm.
Control unit
Lines
Line 1
Line 16
Line type
Line termination
Line name
Paste on
REF. 8.1.1
REF. 8.1.2
REF. 8.1.3
REF. 8.1.4
Instantaneous
Standard
Vibration
Wire
Def.laod V=yes X=no
Impulses 08
Int. time 30 s
Car.Def. V=si X=no
Sensitivity 40ms
Impulses 08
Int. time 30 s
Self-exclusion
Yes / No
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fracarro CE2N-416 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fracarro CE2N-416 in the language / languages: English as an attachment in your email.

The manual is 4,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info