Annex
HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE
All floor protection must be non-combustible (i.e., metals, brick, stone, mineral fiber boards, etc.). Any organic materials (i.e.,
plastics, wood paper products, etc.) are combustible and must not be used. The floor protection specified includes some form of
thermal designation such as R-value (thermal resistance) or k-factor (thermal conductivity).
A. PROCEDURE
1. Convert specification to R-value:
I. R-value given - no conversion needed.
II. k-factor is given with a required thickness (T) in inches:
III. K-factor is given with a required thickness (T) in inches
IV. r-factor is given with a required thickness (T) in inches:
R = r x T
2. Determine the R-value of the proposed alternate floor protector.
I. Use the formula in step (1) to convert values not expressed as “R”.
II. For multiple layers, add R-values of each layer to determine overall R-value.
3. If the overall R-value of the system is greater than the R-value of the specified floor protector, the alternate is acceptable.
EXAMPLE: The specified floor protector should be 3/4-inch thick material with a k-factor of 0.84. The proposed alternate is
4” brick with an r-factor of 0.2 over 1/8” mineral board with a k-factor of 0.29.
Step (a): Use formula above to convert specification to R-value.
Step (b): Calculate R of proposed system.
4” brick of r = 0.2, therefore:
1/8” mineral board of k = 0.29, therefore
Rtotal = Rbrick + Rmineral board = 0.8 + 0.431 = 1.231
Step (c): Compare proposed system Rtotal of 1.231 to specified R of 0.893. Since proposed system Rtotal is greater than
required, the system is acceptable.
B. DEFINITIONS
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Focus Agorafocus 630 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Focus Agorafocus 630 in the language / languages: English as an attachment in your email.

The manual is 5.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info