624069
21
Zoom out
Zoom in
Previous page
1/36
Next page
Set Up the Tester
13
PoE Configuration
Select Tools > PoE Configuration.
ffy34.bmp
Figure 8. PoE Configuration Screen
By default, PoE is disabled. This screen allows you to enable/
disable PoE dete
ction, Enable TruePower
TM
, and set the Class
for detection. If you enable PoE and select Class 4 (25.5W),
you can also enable LLDP Negotiation so that PoE is only
reported if that criteria is met.
PoE TruePower
TM
is only available on the LR-AT 2000 model.
TruePower
TM
puts a load on the PoE device and gives an
accurate measurement on whether the device supports the
Class selected.
Connect Configuration
Select Tools > Connect Configuration.
ffy43.bmp
Figure 9. Connect Configuration Screen
This screen allows you to enable 802.1x Authentication and
set the speed/Duplex.
For 802.1x Authentication, if a certificate is required, you
must transfer it from your PC using the LinkRunner
Manager PC application provided with LR-AT. Only one
certificate can be installed on a LR-AT at a time.
For Speed & Duplex, Auto is the default and recommended
configuration. 10 HDX is 10 Mbps half duplex, 1000 FDX is
1000 Mbps full duplex.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke networks LinkRunner AT 2000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke networks LinkRunner AT 2000 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info