LinkRunner AT 1000/2000 Network Auto-Tester
Users Manual
12
VLAN/MAC Configuration
Select Tools > VLAN/MAC Configuration.
ffy41.bmp
Figure 6. VLAN/MAC Configuration Screen
This screen allows you to enable and enter the VLAN IP and
its Priority level. By un-checking the VLAN check box, the
VLAN capability is disabled.
This screen also allows you to enable and enter a user
defined MAC address. By un-checking the Enable User
Defined MAC check box, the LR-AT reverts back to the
factory default MAC address.
AutoTest Configuration
Select Tools > AutoTest Configuration.
ffy42.bmp
Figure 7. AutoTest Configuration Screen
This screen allows you to enter up to ten key device
addresses
(Targets) to test connectivity. You may enter an IP
address, URL, or DNS name. If no port is specified, AutoTest
will perform an ICMP Ping test to that address. If a port is
specified, AutoTest will perform a TCP Connectivity test
(SYN/ACK).
The Continuous Mode check box allows the test to run
continuously (checked) or one time (un-checked). When
you exit the AutoTest screen, the test is stopped.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke networks LinkRunner AT 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke networks LinkRunner AT 1000 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info