DTX Series CableAnalyzer
Technical Reference Handbook
C-2
1 Jumper Method
Results from the 1 Jumper method account for the loss of
two connections plus the fiber in the link. This method is
suitable for testing premises fiber, where patch cords are
typically used at both ends of the link and connector loss is
a significant portion of the total loss. Appendix B shows the
names of the standards that define the 1 Jumper method.
Reference connections for the 1 Jumper method cancel out
the effects of the test reference cords, as shown in Figure C-
1.
Loss results for the 1 Jumper method therefore represent
both connections plus the fiber in the link. Industry
standards specify the 1 Jumper method for testing
multimode and singlemode premises fiber, where
connector loss is a significant portion of the total loss.
Note
Other methods are available for getting 1 Jumper
results when you do not have the correct
connector adapters for the tester. See "Modified 1
Jumper Method" on page C-8. For additional
methods, see the Fluke Networks Knowledge Base.
376


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke networks DTX CableAnalyzer Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke networks DTX CableAnalyzer Series in the language / languages: English as an attachment in your email.

The manual is 10,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info