CableIQ Qualification Tester
Users Manual
56
Locating Crosstalk and Impedance
Faults on Twisted Pair Cabling
The Find Crosstalk Fault and Find Impedance Fault
functions let you quickly check cable pairs for crosstalk
and impedance faults on twisted pair cabling.
Crosstalk is unwanted signal transmission between cable
pairs. Crosstalk can cause transmission errors in twisted
pair networks.
Impedance is electrical resistance to ac signals, such as
data and CATV transmissions. Impedance changes cause
signal reflections that can disrupt network operation and
cause poor CATV reception.
To find crosstalk or impedance faults:
Note
If you use patch cords at the near or far end
during crosstalk or impedance tests, Fluke
Networks recommends patch cords at least 2 m
long.
1 Connect the tester to twisted pair cabling. A
wiremap adapter or ID locator is not required.
2 Turn the rotary switch to DIAG.
3 Use D to highlight Find Crosstalk Fault or Find
Impedance Fault; then press H or J.
4 To change the transmission standard, press H or
J, use AD to select a standard; then press
H.
5 To select a cable pair or pairs to test, press D to
highlight the pair(s), press H or J, use AD
to select a pair or pairs; then press H.
6 Press P to start the test.
Table 3 describes the crosstalk and impedance fault
messages.
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke networks CableIQ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke networks CableIQ in the language / languages: English as an attachment in your email.

The manual is 1.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info