Autotest
Autotest Results for Twisted Pair Cabling
3
3-21
ACR@REMOTE
The ACR@REMOTE test is identical to the ACR test, except that the ACR values
are calculated using NEXT@REMOTE values.
Return Loss (RL)
The RL test measures the difference between a test signals amplitude and the
amplitude of signal reflections returned by the cabling. The results of the RL test
indicate how well the cables characteristic impedance matches its rated
impedance over a range of frequencies.
The first RL results screen shows the cable pairs tested, the worst-case RL margin,
and a PASS or FAIL result for each pair. To see detailed results for the cable
pairs, use D U to highlight a pair; then press @ View Result. Table 3-6
describes the items on the RL results screen.
For TIA and ISO test standards, RL is not evaluated where attenuation at the same
frequency is less than 3 dB.
Table 3-6. Items on the RL Results Screen
Item Description
Pair
The cable pair relevant to the results.
Result
The overall result for the RL test. A PASS result means that the measured RL
is lower than the specified limit for the selected test standard. A FAIL result
means that the measured RL is higher than specified limit.
RL
The worst margin and worst RL. The worst margin is the RL value that is
closest to falling below specifications, or the value that exceeds specifications
by the greatest amount. The worst RL is the lowest RL value measured.
Frequency
The frequencies where the worst margin and worst RL values occurred.
Limit
The lowest acceptable RL values for the frequencies above.
Margin
The differences between the RL values and the limits. A positive number
means that the worst-case RL is better than the limit. A negative number
means that the worst-case RL exceeds the limit.
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke DSP-4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke DSP-4000 in the language / languages: English as an attachment in your email.

The manual is 2,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke DSP-4000

Fluke DSP-4000 Quick start guide - English - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info