624057
80
Zoom out
Zoom in
Previous page
1/216
Next page
DSP-4000 Series
Users Manual
3-14
NEXT Test
The NEXT test measures the crosstalk between cable pairs at the near end of the
cabling. This crosstalk value is expressed as the difference in amplitude (in dB)
between the test signal and the crosstalk signal. NEXT is measured from both ends
of the cabling over a frequency range defined by the selected test standard.
The first NEXT screen displays the cable pairs tested, the worst-case NEXT
margin, and the test result for each set of pairs.
To see detailed results for the cable pairs, use D U to highlight the pairs; then
press @ View Result. Table 3-3 describes the items on the NEXT results
screen.
For ISO/IEC 11801-2002 and EN50173:2002 standards, NEXT is not evaluated
where attenuation at the same frequency is less than 4 dB.
Table 3-3. Items on the NEXT Results Screen
Item Description
Pairs
The cable pairs relevant to the results.
Result
The overall result for the NEXT test. A PASS result indicates that the NEXT
between the cable pairs was higher than the specified NEXT for the selected
test standard. A FAIL result indicates that the NEXT was lower than
specifications.
NEXT
The worst margin and worst NEXT. The worst margin is the NEXT value that is
closest to falling below specifications, or the value that exceeds specifications
by the greatest amount. The worst NEXT is the lowest NEXT value measured.
Frequency
The frequencies where the worst margin and worst NEXT values occurred.
Limit
The lowest NEXT values acceptable for the frequencies above.
Margin
The differences between the NEXT values and the limits. A positive number
means that the measured NEXT value is higher than the limit (PASS). A
negative number means that the NEXT is lower than the limit (FAIL).
80


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke DSP-4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke DSP-4000 in the language / languages: English as an attachment in your email.

The manual is 2,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke DSP-4000

Fluke DSP-4000 Quick start guide - English - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info