Getting Started
Configuring the Test Tool
2
2-35
Selecting a Test Standard and Cable Type
The test standard and cable type you select determine which standards are used
and which tests are run during cable testing. The test tool is equipped with
information for all the common test standards and cable types.
Several of the test standards for twisted pair cable are defined for both a channel
and a permanent link configuration. The test limits for a channel are looser than
those for a permanent link because the channel limits allow for the effects of two
connections at a horizontal cross-connect and a transition connector near the
telecommunications outlet in the work area. Figures 2-5 and 2-6 earlier in this
chapter show the connections involved in a permanent link and a channel. Chapter
7 further explains these connections.
Note
The test tool displays a message if you try to run a test not supported by the
attached link interface adapter.
To select a test standard and cable type, proceed as follows:
1. Turn the rotary switch to SETUP.
2. Press ! Choice. The standards list starts with the last five standards
used. Press $ Page Down to see more standards.
3. Use D U to highlight the test standard you want.
4. Press E to accept the highlighted test standard. The test tool displays a
menu of the cable types valid for the selected test standard.
5. Use D U to select the cable type you want; then press E.
6. If you selected a shielded cable type, the next display lets you enable or
disable the shield test. Use D U to select the setting you want; then press
E.
You can test cables for NEXT, ELFEXT, PSNEXT, ELFEXT, attenuation, and
ACR, and PSACR up to 350 MHz. Test limits apply only up to the frequency
specified by the selected test standard.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke DSP-4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke DSP-4000 in the language / languages: English as an attachment in your email.

The manual is 2,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke DSP-4000

Fluke DSP-4000 Quick start guide - English - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info