Quick Configuration
The settings listed in Table 2-3 affect either the display format or the accuracy of
your test results. Following the table are instructions for changing the settings. For
a complete list of the test tools adjustable settings, refer to the later section
“Setup.”
Table 2-3. Quick Configuration Settings
SETUP Setting Description
Test Standard
and Cable Type
Select the test standard and cable type you are using. Fiber optic cable
testing requires a Fluke Networks DSP-FTA Fiber Test Adapter or a
Fluke Networks DSP-FOM (Fiber Optic Meter; comes with the DSP-FTK).
Report
Identification
Enter your company’s name, operators’ names, and site names. These
names appear in the Autotest reports you save.
Auto Increment
(cable ID setup)
Enabling this setting causes the last character of the cable ID to
increment each time you save an Autotest. The Sequence selection lets
you define a range of cable IDs by entering a start and end ID. On a
DSP-4300, the Cable ID List selection lets you select a list of IDs that was
created and saved on a memory card with LinkWare software.
Store Plot Data
(DSP-4100/4300)
Enable this setting to store plot data (from tests such as attenuation,
return loss, and NEXT) with Autotest results saved on a DSP-4100 or
DSP-4300 test tool.
Length Units Select meters or feet as the unit for length measurements.
Numeric Format Select a format (0.00 or 0,00) for display of decimal fractions.
Display and
Report Language
Select English, German, French, Spanish, Italian, Portuguese, or
Japanese.
Power Line Noise
Filter Frequency
Select the frequency of the ac power in your area. The test tool filters out
50 Hz or 60 Hz noise from measurements.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke DSP-4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke DSP-4000 in the language / languages: English as an attachment in your email.

The manual is 2,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke DSP-4000

Fluke DSP-4000 Quick start guide - English - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info