624055
12
Zoom out
Zoom in
Previous page
1/190
Next page
DSP-100/2000
Users Manual
1-2
Produces 2-way Autotest results in approximately 20 seconds.
Includes a stored library of common test standards and cable types.
Allows for configuration of up to 4 custom test standards.
Time Domain Crosstalk (TDX
)
analyzer locates the position of crosstalk
(NEXT) problems on a cable.
Tests for return loss (RL).
Produces plots of NEXT, attenuation, ACR, and RL. Shows NEXT, ACR, and
attenuation results up to 155 MHz.
Stores at least 500 cable test results in nonvolatile memory.
Monitors impulse noise and network traffic on Ethernet systems. Hub port
locator helps you identify port connections.
Sends stored test reports to a host computer or directly to a serial printer.
Flash EPROM accepts test standard and software upgrades.
Tests fiber optic cable when used with a Fluke DSP Fiber Optic Meter.
Model DSP-2000 includes the following additional features:
Monitors 100BaseTX network traffic.
Diagnostic routine provides specific information about the location and cause
of an Autotest failure.
Tests for remote return loss (RL@REMOTE) and power sum NEXT
(PSNEXT).
Determines which standards are supported by a hub port connection.
Tone generator lets you use an inductive pickup device to identify cables in a
LAN installation.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke DSP-100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke DSP-100 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info