763940
80
Zoom out
Zoom in
Previous page
1/100
Next page
8808A
Users Manual
4-20
Table 4-10. Function Modifier Commands and Queries (cont.)
Command Description
HOLDTHRESH? Meter returns Touch Hold <threshold> (1, 2, 3, or 4). See “Touch Hold
Function (HOLD)” in Chapter 3 for more information.
MAX Meter enters MAX modifier with present reading as maximum value. If already
in MAX modifier, Meter displays maximum value. In MAX modifier,
autoranging is disabled. See “Minimum / Maximum Modifier (MIN MAX)” in
Chapter 3 for more information.
MAXSET <numeric value> Meter enters MAX modifier with <numeric value> as the maximum value.
<numeric value> can be a signed integer, signed real number without
exponent, or signed real number with exponent. Autoranging is disabled. See
“Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for more information.
If <numeric value> exceeds the measurement range, an Execution Error is
generated.
MIN Meter enters MIN modifier with present reading as minimum value. If already
in MIN modifier, Meter displays minimum value. In MIN modifier, autoranging
is disabled. See “Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for
more information.
MINSET <numeric value> Meter enters MIN modifier with <numeric value> as the minimum value.
<numeric value> can be a signed integer, signed real number without
exponent, or signed real number with exponent. Autoranging is disabled. See
“Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for more information.
If <numeric value> exceeds the measurement range, an Execution Error is
generated.
MNMX Meter enters MIN MAX modifier with present reading as minimum and
maximum value. If already in MIN MAX modifier, Meter displays latest MIN or
MAX value. In MIN MAX modifier, autoranging is disabled. See “Minimum /
Maximum Modifier (MIN MAX)” in Chapter 3 for more information.
When the MIN MAX modifier is selected, you can toggle between displaying
the minimum and maximum readings without losing the minimum and
maximum values stored.
MNMXSET <numeric1,
numeric2>
Meter enters MIN MAX modifier with <numeric1> as the maximum value and
<numeric2> as the minimum value.
<numeric1> and <numeric2> can be signed integer, signed real number
without exponent, or signed real number with exponent. Autoranging is
disabled. See “Minimum / Maximum Modifier (MIN MAX)” in Chapter 3 for
more information.
If <numeric1> or <numeric2> exceeds the measurement range, an Execution
Error is generated.
MMCLR Meter exits the MN MX modifier. The stored minimum and maximum values
are lost, and the Meter returns to the ranging mode and range selected prior
to selecting MN MX modifier.
80


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8808A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8808A in the language / languages: English as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8808A

Fluke 8808A User Manual - German - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info