763944
17
Zoom out
Zoom in
Previous page
1/134
Next page
Reference Multimeter and 8 ½ Digit Multimeter
Front and Rear Panel
13
Table 3. Front-Panel Features (cont.)
Number Name Function
U
Triggers a measurement when the Product is in the non-continuous
trigger (idle) state. The idle state occurs when the Run/Stop key is
pushed once. is one of the few keys that is not disabled
when in Remote operation. See Triggering Measurements for details
about the Product Trigger subsystem. starts data capture
when in digitize.
V
Five softkeys that select the menu item noted directly above each
respective key.
W GROUND
Five-way binding post connected to earth ground through the earth
ground connector on the mains plug. This terminal does not
illuminate.
X GUARD
This five-way binding post in the External Guard OFF state is
isolated from any internal connections, and the internal guard
shields are connected to the internal 0 V. In the External Guard ON
state, the internal guard shields are disconnected from the internal
0 V and connected to the GUARD terminal of the selected front or
rear input. In the Ohms or PRT functions, the External Guard ON
selection is modified to provide an ohms guard. To set the condition
of the External Guard (ON or OFF) push to access
(Ext. Guard). Guarding is explained throughout this manual. When
set to Ext. Guard ON, this terminal illuminates.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8558A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8558A in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8558A

Fluke 8558A User Manual - German - 134 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info