ProcessMeterâ„¢
Measuring Electrical Parameters
19
Testing Diodes
To test a single diode:
1. Insert the red test lead into the Vjack and
black test lead into the COM jack.
2. Set the rotary switch to O.
3. Press the BLUE pushbutton so that the D
symbol is on the display.
4. Touch the red probe to the anode and the black
probe to the cathode (side with band or bands). The
Meter should indicate the appropriate diode voltage
drop.
5. Reverse the probes. The Meter should display OL,
indicating high impedance.
6. The diode is good if it passes the tests in steps 4
and 5.
Displaying Minimum, Maximum, and Average
MIN MAX recording stores the lowest and highest
measurements, and maintains the average of all
measurements.
Press M to turn on MIN MAX recording. Readings
are stored until you turn the Meter off, switch to another
measurement or source function, or turn MIN MAX off.
The beeper sounds when a new maximum or minimum is
recorded. Auto power-off is disabled and auto ranging is
turned off during MIN MAX recording.
Press M again to cycle through the MAX, MIN, and
AVG displays. Press and hold M for 1 second to
erase stored measurements and exit.
If MIN MAX recording is on continuously for over
40 hours, minimum and maximum readings are still
recorded, but the displayed average no longer changes.
In MIN MAX recording, press I to suspend
recording; press I again to resume recording.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 787 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 787 in the language / languages: English as an attachment in your email.

The manual is 4,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 787

Fluke 787 User Manual - German - 52 pages

Fluke 787 User Manual - Dutch - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info