4
Battery Saver (Sleep Mode)
The Meter enters the "Sleep" mode and blanks out the display if
there is no function change or button press for 20 minutes. To
disable the Sleep mode, hold down the yellow button while turning
the Meter on. The Sleep mode is always disabled in the MIN MAX
AVG mode and the AutoHOLD mode.
Terminals
.
FUSED
V
1
2
3
4
AIK01F.EPS
Item Description
1 Input terminal for AC and DC milliamp measurements to
400 mA.
2 Input terminal for AC and DC current measurements to
10 A.
3 Input terminal for voltage, continuity, resistance, diode
test, capacitance, and frequency measurements.
4 Common (return) terminal for all measurements.
Rotary Switch Positions
Switch
Position Measurement Function
Hz
AC voltage from 0.001 to 1000 V.
Frequency from 2 Hz to 99.99 kHz.
DC voltage from 1 mV to 1000 V.
m DC mV from 0.1 mV to 600 mV.
e
Ohms from 0.1 Ω to 50 MΩ.
Farads from 1 nF to 9999 μF.
R
Beeper turns on at <25 Ω and turns off at >250 Ω.
Diode test. Displays OL above 2.4 V.
mA
AC mA from 0.01 mA to 400 mA.
DC mA from 0.01 mA to 400 mA.
A
AC A from 0.001 A to 10 A.
DC A from 0.001 A to 10 A
>10.00 display flashes.
>20 A, OL is displayed.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 77 Series IV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 77 Series IV in the language / languages: English as an attachment in your email.

The manual is 3,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 77 Series IV

Fluke 77 Series IV User Manual - German - 22 pages

Fluke 77 Series IV User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info