Documenting Process Calibrator
Operation Features
13
Operation Features
Input and Output Jacks
Figure 4 shows the input and output jacks and connectors.
Table 3 explains their use.
Table 3. Input/Output Jacks and Connectors
No. Name Description
HART jack (754 only) Connects the Product to HART devices.
Pressure module
connector Connects the Product to a pressure module.
TC input/output
Jack to measure or simulate thermocouples. This jack accepts a miniature
polarized thermocouple plug with flat, in-line blades spaced 7.9 mm (0.312 in)
center to center.
, MEASURE V jacks Input jacks to measure voltage, frequency, or three- or four-wire RTDs
(Resistance Temperature Detectors).
,
SOURCE mA,
MEASURE mA Ω RTD
jacks
Jacks to source or measure current, measure resistance and RTDs, and supply
loop power.
, SOURCE V Ω RTD
jacks Output jacks to source voltage, resistance, frequency, and to simulate RTDs.
Battery Charger jack
Jack for the battery charger/universal power supply (referred to as the battery
charger throughout this manual). Use the battery charger for bench-top
applications where ac line power is available.
USB port (Type 2) Connects the Product to a USB port on a PC.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 753 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 753 in the language / languages: English as an attachment in your email.

The manual is 5,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 753

Fluke 753 User Manual - German - 130 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info