721Ex
Users Manual
4
Ex-Hazardous Areas
An Ex-hazardous area as used in this manual refers to an
area made hazardous by the potential presence of
flammable or explosive vapors. These areas are also
referred to as hazardous locations.
The Product has been designed for use in Ex-Hazardous
Areas. These are areas where potentially flammable or
explosive vapors may occur. These areas are referred to
as hazardous (classified) locations in the United States,
as Hazardous Locations in Canada, as Potentially
Explosive Atmospheres in Europe and as Explosive Gas
Atmospheres by most of the rest of the world. The
Product is designed as intrinsically safe. This means that
connecting the Product to equipment that is used within
intrinsically-safe circuits will not cause an ignition-capable
arc as long as the entity parameters are suitably
matched.
 Warning
To prevent possible personal injury, check
entity parameters before making any
connections to this device.
Measuring Pressure
Warning
For safe operation and maintenance of the
Product, Refer to the table of ranges and
resolutions at the back of the manual for
information about overpressure and burst
pressure ratings. Pressure sensors can be
damaged and personnel injury can occur due
to improper application of pressure. Vacuum
should not be applied to any gauge pressure
sensor. The Product display shows “OL”
when an inappropriate pressure is applied. If
“OL” is seen on any pressure display, reduce
or vent pressure immediately to prevent
equipment damage or possible personnel
injury. “OL” is shown when pressure >120 %
of the nominal range of the sensor or when a
vacuum >2 PSI is applied on gauge range
sensors.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 721Ex at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 721Ex in the language / languages: English as an attachment in your email.

The manual is 1,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 721Ex

Fluke 721Ex User Manual - German - 46 pages

Fluke 721Ex User Manual - Dutch - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info