764277
14
Zoom out
Zoom in
Previous page
1/22
Next page
707Ex
Gebruiksaanwijzing
10
HART-compatibiliteit
In de aanvoermodus heeft het ijkinstrument een
serieweerstand van > 250 Ω en is het compatibel met
HART-apparaten zonder dat een extra serieweerstand
nodig is.
V dc meten
W Let op
Om te voorkomen dat de te testen apparatuur
wordt beschadigd, zet u het ijkinstrument in
de juiste modus voordat u de meetkabels
aansluit.
Ga als volgt te werk om V dc te meten.
1. Druk op A om naar de modus MEASURE (meten) te
gaan.
2. MEASURE V verschijnt.
3. Laat de probes van de meetkabels contact maken
over de belasting of stroombron. Sluit de COM-probe
eerst aan.
707Ex
mA CALIBRATOR
28 V dc max.
COM
+
Toets indrukken totdat
MEASURE V verschijnt.
ARD01F.EPS
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 707Ex at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 707Ex in the language / languages: Dutch as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 707Ex

Fluke 707Ex User Manual - English - 22 pages

Fluke 707Ex User Manual - German - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info