Users Manual
12
Timer
Fluke recommends that you use a time-delay for the most
accurate measurements at long distances. This prevents Meter
movement when you push .
To turn on the timer:
1. Push 1x to turn on the 5-second timer. This is the default
time interval to release the laser for a measurement.
2. Push or to adjust the timer up to 60 seconds.
3. Push to begin the timer.
The seconds until measurement (for example, 59, 58, 57...)
show as a countdown. The last 5 seconds count down with a
beep. After the last beep, the Meter makes the measurement
and the value shows on the display.
Note
The timer is useful for all measurements.
Beeper
Push at the same time for 2 seconds to turn on and turn off
the beeper. The display shows the status as   or 
.
Measurements
The Meter measures the distance to a target, the area bounded
by two distances, or the volume in three measurements.
Single Distance Measurement
To measure distance:
1. Push to turn on the laser.
2. Push again to make the distance measurement.
The measurement shows on the display.
Note
Measurement errors can occur if you point the laser at
colorless liquids, glass, polystyrene, semi-permeable
surfaces, and high-gloss surfaces. The measurement time
increases when you point the laser at dark surfaces.
A target plate is useful for long distance measurements if the
target reflectivity and illumination is a problem.
Continuous Measurement
Use continuous measurement to make a series of quick
measurements. For example, to mark stud positions along a wall
plate.
To start continuous measurement:
1. While the meter is on, push for 2 seconds.
2. Move the laser to each position and view each
measurement.
The Meter continuously shows measurements until you push
or < or the Meter times out.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 417D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 417D in the language / languages: English as an attachment in your email.

The manual is 6,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 417D

Fluke 417D User Manual - German - 28 pages

Fluke 417D User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info