764245
9
Zoom out
Zoom in
Previous page
1/22
Next page
Clamp Meter
Before You Start
5
Terms to Know
Use this section to familiarize yourself with these terms that are
unique to this Product.
FieldSense™ Technology/Non-contact voltage (NCV)
Measurement. Voltage measurements by capacitive sensing
technology that completes galvanic isolation. This technology uses
capacitive sensors for measuring AC voltages through non-
galvanic contact, coupled with a Hall Effect jaw that allows
simultaneous current measurements. It enables minimizing
voltage probes connections, therefore reducing hazardous
situations and saving setup-up time, and circuit or machine
downtime. Fluke-developed icon for FieldSense technology is U.
L1-L2-L3. L1, L2, and L3 (or Line 1, Line 2, and Line 3) is a
common naming convention for the wires in three-phase
alternating current (ac) systems. The Clamp features a sequential
line-to-ground measurement that results in a calculated line-to-line
voltage measurement. This voltage measurement is an indication
that the three-phase system is, or is not, working as expected.
Power Factor. Power factor (PF) is the ratio of working power,
measured in kilowatts (kW), to apparent power, measured in
kilovolt amperes (kVA). PF expresses the ratio of true power used
in a circuit to the apparent power delivered to the circuit.
Fluke Connect™App. Fluke Connect is a system that wirelessly
connects your Clamp with an app on your smartphone or tablet.
THD. The total harmonic distortion is a measurement of the
harmonic distortion present in a signal and is defined as the ratio
of the sum of the powers of all harmonic components to the power
of the fundamental frequency.
Fluke Connect™ (377 FC/378 FC)
Fluke Connect™ software (may not be available in all regions)
supports the Clamp to wirelessly connect to a mobile app. The app
shows the measurements and other data on your smartphone or
tablet display. You can share this data with your team and save
collected measurements and calculations to the Fluke Connect
Cloud.
Fluke Connect uses low-power 802.15.4 wireless radio technology
to connect the Clamp with an app on your smartphone or tablet.
The wireless radio does not cause interference with Clamp
measurements.
Radio Frequency Data
Note
Changes or modifications to the wireless 2.4 GHz
radio not expressly approved by Fluke Corporation
could void the user’s authority to operate the
equipment.
For complete information about radio frequency data, go to
www.fluke.com/manuals and search for “Radio Frequency Data
Class A”.
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this
Product is in compliance with Directive 2014/53/EU. The full text of
the EU declaration is available at the following internet address:
www.fluke.com/declaration-of-conformity
Fluke Connect™ Mobile App
The Fluke Connect™ app works with Apple and Android mobile
products. The app is available for download to your smart device
from the Apple App Store and Google Play.
To use the Fluke Connect app:
1. Open the Fluke Connect app on your device.
2. Turn on the Clamp.
3. Push F to activate the radio on the Clamp. E shows on the
display.
4. On your smartphone, go to Settings > Bluetooth.
5. Verify that Bluetooth is turned on.
6. Go to the Fluke Connect App and in the list of connected
Fluke tools, select 377 FC/378 FC.
You can now take, save, and share measurements with the
app. Go to www.flukeconnect.com for more information about
how to use the app.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 377 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 377 in the language / languages: English as an attachment in your email.

The manual is 2,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 377

Fluke 377 User Manual - German - 22 pages

Fluke 377 User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info