764256
15
Zoom out
Zoom in
Previous page
1/28
Next page
November 2015 Rev. 1, 6/19
©2015-2019 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
368/368 FC
369/369 FC
AC Leakage Current Clamp
Users Manual
Users Manu
a
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one year from
the date of purchase. This warranty does not cover fuses, disposable batteries, or damage
from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To
obtain service during the warranty period, contact your nearest Fluke authorized service
center to obtain return authorization information, then send the product to that Service Center
with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS
NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or
countries do not allow the exclusion or limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may not apply to you.
11/99
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
ООО «Флюк СИАЙЭС»
125167, г. Москва, Ленинградский
проспект дом 37,
корпус 9, подъезд 4, 1 этаж
i
Title Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How to Contact Fluke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
The Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Manual-Range Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Clean the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AC Current Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Safety Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Wireless Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Operational Error for Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Product Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table of Contents
368/368 FC/369/369 FC
Users Manual
ii
1
Introduction
The 368/368 FC and 369/369 FC AC Leakage Current Clamp (the Product) is a handheld tool for
measurement of ac leakage current.
Principle of Leakage Current Measurement
Based on the electromagnetic induction principle, the Product has a ring-shape current transformer
comprised of a metal core and coil winding. The current transformer senses the magnetic field produced
by the current or by the vector sum of the currents flowing in the conductor under test. The current
transformer then produces a current proportional to the current flowing in the conductor.
See the Product Functions section near the end of this manual.
368/368 FC/369/369 FC
Users Manual
2
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
China: +86-400-921-0835
Brazil: +55-11-3530-8901
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com.
To register your product, visit http://register.fluke.com.
To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals.
Safety Information
General Safety Information is in the printed Safety Information document that ships with the Product and
at www.fluke.com. More specific safety information is listed where applicable.
AC Leakage Current Clamp
Product Overview
3
Product Overview
Table 1 and Figure 1 explain the Product features.
Table 1. Features
Item Definition
Keep fingers below the Tactile Barrier.
Push to retain the measured data on the display. When pushed, shows on
the display. When pushed again, data hold is canceled and disappears.
The display shows the measured value (digital reading), unit, function, and low battery
symbol.
Push to choose the range of ac current (either mA or A). Push and hold for
2 seconds to turn on the filter.
368 FC/369 FC: Log data and clear memory, see Product Functions.
368 FC/369 FC: Turn on/turn off the Fluke Connect™ wireless connectivity to a
smartphone, see Product Functions.
368/368 FC/369/369 FC
Users Manual
4
Push to show the minimum, maximum, and average reading. When pushed,
shows on the display.
Push to turn on the display backlight. Push and hold for 2 seconds to turn on the
spotlight. See Spotlight.
Push to turn on or turns off the Product.
Jaw trigger
Push the jaw lock button and the trigger together to unlock the jaw.
Spotlight. See Spotlight.
Jaw
Battery Housing holds the batteries. See Batteries.
Table 1. Features (cont.)
Item Definition
AC Leakage Current Clamp
Product Overview
5
Figure 1. Product Features
1
13
12
9
3
23
4
7
8
9
10
11
14
3
4
3
5
6
368/368 FC/369/369 FC
Users Manual
6
The Display
Table 2 and Figure 2 explain the Product display.
Table 2. Display
Item Definition
Battery Symbol
Main display
The Product is searching for ranges.
Fluke Connect on (368 FC and 369 FC)
Min, Max, or Avg reading is showing.
MinMax mode is active.
Hold mode is active.
Filter is active and filters signals from 40 Hz – 70 Hz.
mA AC or A AC
Remaining memory (368 FC and 369 FC)
Product identification number when used with Fluke Connect (368 FC and 369 FC).
AC Leakage Current Clamp
The Display
7
Figure 2. Display
1
2
3
678
5
4
9
11
10
368/368 FC/369/369 FC
Users Manual
8
Manual-Range Mode
To enable manual-range mode:
1. With the Product off, simultaneously push and .
2. Hold both buttons until the backlight illuminates (~2 s).
The Product is now in manual-range mode.
3. Push to select the range.
Clean the Product
Periodically wipe the case with a damp cloth and mild detergent.
W Caution
To avoid damaging the Product, do not use abrasives or solvents to clean the Product.
1. Inspect the jaw mating surface for cleanliness. If any foreign material is present, the jaw will not
close properly and measurement errors will result.
2. Open the jaws and clean the clamp metal ends with a lightly oiled cloth.
AC Leakage Current Clamp
Maintenance
9
Maintenance
If the Product does not work or perform properly, use these steps to help isolate the problem:
1. Inspect the jaw mating surface for cleanliness. If any foreign material is present, the jaw will not
close properly and measurement errors will result.
2. Verify that the range on the Product is correct.
Replacement Parts
Replacement parts are listed in Table 3. To order, see How to Contact Fluke.
Table 3. Replacement Parts
Item Description Fluke Part Number
Battery 2AA IEC LR6 Alkaline 376756
Battery door assembly
English 4700598
Chinese 4739829
368/368 FC/369/369 FC
Users Manual
10
Specifications
General
Measurement functions ........................AC current
Display (LCD) .......................................Digital reading: 3300 counts, LCD refresh rate 4x/s
Range selection....................................mA/A: manual selection
3 mA/30 mA/300 mA: auto selection
3 A/30 A/60 A: auto selection
Battery
Type ................................................. 2 AA IEC LR6 alkaline
Life.................................................... >150 hours without backlight and spotlight
Maximum conductor diameter ..............368: 40 mm, 369: 61 mm
Automatic power off..............................15 minutes after the last switch operation
AC Leakage Current Clamp
Specifications
11
Dimensions
369/369 FC (W x H x D) ................... 116 mm x 257 mm x 46 mm
368/368 FC (W x H x D) ................... 101 mm x 234 mm x 46 mm
Weight
369/369 FC....................................... 600 g
368/368 FC....................................... 500 g
Electrical Specifications
Reference Conditions...........................23 ±5 °C and 80 % RH maximum
A AC Range .........................................3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Frequency ............................................40 Hz to 1 kHz
Crest Factor..........................................3
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 368 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 368 in the language / languages: English as an attachment in your email.

The manual is 3,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 368

Fluke 368 User Manual - German - 28 pages

Fluke 368 User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info