switch position Push once to turn on the backlight and push again to turn off the backlight. The backlight
turns off automatically after 2 minutes.
All positions Starts the MIN MAX record function. Steps the display through MAX, MIN, AVG (average),
and input signal measurement. Push for 1 second to stop MIN MAX record.
Not related to
switch position Selects the highlighted radio mode and selects/deselects the highlighted wireless test tool
on the display.[2]
Not related to
switch position •Moves the highlight on the display to the next radio mode or wireless test tool shown in
the display.
•Hold for 1 second to pair all selected test tools to the Product and stop the discovery
procedure.[2]
Not related to
switch position •Turns on the radio and shows the radio mode selection screen. shows on the display
when the radio is on.
•In App mode, sends the measurement to the Fluke Connect App on mobile device.
•Push and hold for 1 second to turn off the radio when radio is on.[2]
[1] This function stays in ac or dc when the function switch is moved to another position and back to this function. Even when turned to off and back to this
function.
[2] This button is used when the Product connects with a wireless radio. See Wireless Radio Setup on page 13 to learn more.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Fluke 3000 FC at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Fluke 3000 FC in the language / languages: English as an attachment in your email.
The manual is 5,78 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.