763957
34
Zoom out
Zoom in
Previous page
1/88
Next page
287/289
Users Manual
24
To select another reference value, press the softkey labeled Ref
to display a message box with the current reference value.
Pressing 7 or 8, scrolls through the nine predefined references:
4, 8, 16, 25, 32, 50, 75, 600, and 1000. Set the reference by
pressing the softkey labeled OK. To add a custom reference
impedance, see the “Setting a Custom dBm Reference” section
later in this manual.
A dBV measurement uses a 1 volt reference voltage to compare
the present measurement against. The difference between the
two ac signals is displayed as a dBV value. The reference
impedance setting is not part of a dBV measurement.
To make a dBV measurement, position the rotary switch to V or
T and place the Meter leads on the voltage to be measured.
Next, press the softkey labeled Menu. Move the menu selector
to the menu item labeled dBV and press the softkey labeled
dBV. The Meter displays the voltage in dBV.
To exit the dBV or dBm function, press the softkey labeled Menu
followed by the softkey labeled dBV or dBm, respectively.
Selecting one of the other modifiers such as ms, %, or CF also
cancels dBV or dBm.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 289 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 289 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 289

Fluke 289 User Manual - German - 92 pages

Fluke 289 User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info