the softkey labeled Save to store the MIN MAX screen data. MIN
MAX can not be continued at this point. Press the softkey labeled
Close to exit the MIN MAX mode.
Pressing the softkey labeled Restart while MIN MAX is running
stops the MIN MAX session, discards all MIN MAX data, and
immediately starts a new MIN MAX recording session.
Capturing Peak Values
Peak record is almost the same as MIN MAX record explained
earlier in this manual. The significant difference between the two
recording functions is the shorter response time for peak
recording: 250 μs. With this short response time, the actual peak
values of a sinusoidal signal are measurable. Transients are
more accurately measured using the peak record feature.
To activate the peak mode, press the softkey labeled Menu.
Move the menu selector next to the menu item labeled Peak,CF
or Peak. Press the softkey labeled Peak to start the peak
recording session.
Restart
119.8
VAC
Stop
Start : 06/07/07 7:00 pm
Peak Max
168.2
118.9
-173.9
Average
Peak Min
Auto Range
500 VAC
V
VAC
00:03:17
01:10:59
01:10:09
V
8:10pm
06/07/07
Peak
est43.eps
Figure 7. Peak Record Display
As shown in Figure 7, the primary display shows the “live”
measurement present on the Meter’s inputs. In the secondary
area of the display, the maximum and minimum peak values as
well as the average value are shown along with their respective
time stamps. The time stamp next to the average value indicates
the elapsed time of the peak recording session. The peak
recording session start time is shown along the bottom of the
page area of the display.
When the peak value of the input signal goes below the recorded
minimum value or above the recorded maximum value, the Meter
beeps and records the new value. At the same time, the elapsed
time since the peak recording session was started is stored as
the recorded value’s time stamp.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 289 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 289 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 289

Fluke 289 User Manual - German - 92 pages

Fluke 289 User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info