True-rms Digital Multimeters
Selecting the Range
13
recording mode, the time period is five minutes. For MIN MAX,
Peak and AutoHold modes, the time period is the same time the
Auto Off feature is set for. See the “Setting Backlight and Auto
Off Timeouts” section later in this manual. Battery saver mode
conserves battery power by shutting down circuits not necessary
for the selected function, including the display. However, the LED
surrounding the power button (O) will continue to flash to
indicate the Meter is still collecting data.
The Meter “wakes up” from battery-save mode under the
following conditions:
A button is pressed
The rotary knob is moved
A lead is removed or inserted into a current input jack.
The Meter changes range
IR Communications begin
These condictions only awaken the Meter and does not change
the Meter’s function or mode of operation.
Controlling the Backlight
If viewing the display becomes difficult in low-light conditions,
press G to activate the LCD backlight. The backlight button
cycles the backlight through three states: low, high, and off. The
Meter displays a message if the battery level will not support the
backlight operation.
To conserve battery life, a user-adjustable timeout controls how
long the backlight stays on. The default timeout is 5 minutes. To
change the timeout, refer to “Setting Backlight and Auto Off
Timeouts” later in this manual.
Selecting the Range
The Meter’s selected range is always displayed above the right-
hand end of the bar graph, as the range indicator. Pressing R
switches the Meter between manual and autoranging. It also
cycles through the Meter ranges when manual ranging is
enabled.
Note
You cannot use R in conductance, diode test, LoZ,
Low Ohms, and temperature functions. These
functions all use a fixed range.
In autorange, the Meter selects the lowest range to display the
highest available precision (resolution) for the input signal. If
Manual range is already enabled, press and hold R for one
second to enter the autoranging mode.
If autorange is enabled, press R to enter manual ranging.
Each additional press of R sets the Meter to the next higher
range, unless it is already in the highest range, at which point the
range switches to the lowest range.
Understanding Function Menus
Each primary measurement function (rotary switch position) has
a number of optional sub-functions or modes accessed by
pressing the softkey labeled Menu (F1). A typical menu is shown
in Figure 5.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 289 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 289 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 289

Fluke 289 User Manual - German - 92 pages

Fluke 289 User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info