ScopeMeter® Test Tool
Waveform Triggers
43
Waveform Triggers
This section provides an introduction to the trigger functions of the test tool. Triggering tells the
test tool when to begin displaying the waveform. You can use fully automatic triggering, take
control of one or more main trigger functions (semi-automatic triggering), or you can use
dedicated trigger functions to capture special waveforms.
Typical trigger applications:
Use the Connect-and-View function to have full automatic triggering and instant display of
virtually any waveform.
If the signal is unstable or has a very low frequency, you can control the trigger level, slope,
and trigger delay for a better view of the signal. (See next section.)
For dedicated applications, use one of the manual trigger functions:
Edge triggering
Pulse Width triggering
External Triggering (models 190-xx2 only)
Trigger Level and Slope
The Connect-and-View™ function enables hands-off triggering to display complex unknown
signals.
When the test tool is in manual range:
1. Press J to do an auto set.
AUTO appears at the top right of the screen.
Automatic triggering assures a stable display of virtually any signal.
From this point, you can take over the basic trigger controls such as level, slope and delay. To
optimize trigger level and slope manually:
2. Press T to show the TRIGGER key labels.
3. Press 2 to trigger on either positive slope or negative slope of the chosen waveform.
In Dual Slope Triggering (X) the test tool triggers on both positive slope and negative slope.
4. Press 3 to enable the cursor for manual trigger level adjustment.
5. Use h i to adjust the trigger level.
Observe that the trigger icon indicates the trigger position, trigger level, and slope.
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 190-102-III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 190-102-III in the language / languages: English as an attachment in your email.

The manual is 9.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info