775825
55
Zoom out
Zoom in
Previous page
1/98
Next page
ScopeMeter® Test Tool
Waveform Triggers
49
Pulse Triggers
Use pulse width triggering to isolate and display specific pulses that you can qualify by time, such
as glitches, missing pulses, bursts or signal dropouts.
Narrow Pulses
To set the test tool to trigger on narrow positive pulses shorter than 5 ms:
1. Apply a video signal to the red input A.
2. Press T to show the TRIGGER key labels.
3. Press 4 to open the TRIGGER OPTIONS menu.
4. Use the cursor and E select Pulse Width on A to open the trigger on pulse width menu.
5. Use the cursor and E to select the negative pulse icon and jump to Condition.
6. Use the cursor and E to select <t and jump to Update.
7. Use the cursor and E to select On Trigger.
The test tool is now prepared to trigger on narrow pulses only. Observe that the trigger key
labels at the bottom of the screen have been adapted to set the pulse conditions.
To set the pulse width to 100 μs:
8. Press 1 to enable the cursor to adjust the pulse width.
9. Use h i to select 100 μs.
All narrow positive pulses less than 100 μs show on the screen. See Figure 29.
Note
The test tool stores all triggered screens in the replay memory. For example, if you setup
the trigger for glitches, you can capture 100 glitches with time stamps. Use the REPLAY
key to look at all the stored glitches.
Figure 29. Trigger on Narrow Glitches
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 190-062-III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 190-062-III in the language / languages: English as an attachment in your email.

The manual is 9.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info