775825
18
Zoom out
Zoom in
Previous page
1/98
Next page
190 Series III
Users Manual
12
To make motor drive 3-phase current unbalance measurements:
1. Connect the current probes to the Inputs A, B and C.
2. Measure the current of each phase.
To make a motor shaft voltage measurement:
1. Connect the red VPS410-II voltage probe to the input A.
2. Connect the ground lead of the voltage probe to ground.
3. Connect a brush on top of the voltage probe.
4. Place the probe in probe holder.
5. Use the extension rod and magnetic base to keep the probe in a fixed position and the brush
in good contact with the motor shaft.
Probe Type Setup
To obtain correct measurement results the test tool probe type settings must correspond to the
connected probe types.
To select the input A probe setting:
1. Press A to show the INPUT A key labels.
2. Press 3 to open the PROBE ON A menu.
3. Use the cursor and E to select the probe type Voltage, Current, or Temp.
a. Voltage: select the voltage probe attenuation factor.
b. Current and Temp: select the current probe or temperature probe sensitivity.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 190-062-III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 190-062-III in the language / languages: English as an attachment in your email.

The manual is 9.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info