3 Phase Power Quality Analyzer
Basic Setup
39
Communication Settings
These setting relate to communications with the Anaylzer.
Ethernet. The instrument address can be set automatically or manually. The default setting is
Automatic when you select Ethernet from the settings list. For Manual setting, deselect
Ethernet and set the inputs for IP Address, Netmask, Gateway, and DNS.
Note
Only change these settings if you have the required networking knowledge.
A check box allows you to turn off the option for all wireless interfaces when required in
sensitive locations.
WiFi client. This setting directly connects the Anaylzer to the local WiFi network and allows
access to the Anaylzer from any location within the WiFi network. When the WiFi client is off,
the available network access points appear in a list in screen. The network password is
required to connect to the local network. Select the network and enter the password with the
on-screen keyboard. It is not possible to enter a username and password.
WiFi Access Point. The Anaylzer can be set as a WiFi Access point and creates its own WiFi
network that a device can connect to. This can be used to download data from the Anaylzer
with Fluke Energy Analyze software or for control with a Virtual Network Computer. See
Remote Display.
The WiFi direct connection uses WPA2-PSK (pre-shared key) with AES encryption. The
passphrase shown on the screen is required to establish a connection from a client to the
device.
To s e t u p :
1. On the client, go to the list of available WiFi networks and look for the network name:
Fluke177x<serial-no>
For example: Fluke1777<123456789>
2. At the prompt, enter the passphrase provided on the WiFi Configuration screen.
Depending on the operating system of the client, the passphrase is also called Security
Key, Password, or similar.
After a few seconds the connection is established.
Note
On the PC, the WiFi icon in the notification area of the task bar shows (the icon varies
for the Windows version). The icon indicates that this WiFi interface does not provide
an Internet access. This is normal since the Analyzer is not a gateway to the Internet.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 1777 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 1777 in the language / languages: English as an attachment in your email.

The manual is 3.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info