3 Phase Power Quality Analyzer
Before You Start
9
iFlexi Current Probe
The iFlexi Current Probe works on the Rogowski coil (R-coil) principle that is a toroid of wire
used to measure an alternating current through a wire encircled by the toroid. See Figure 5.
Figure 5. R-Coil Operation Principle
The R-coil has advantages over other types of current transformers:
It is not a closed loop. The second terminal is passed back through the center of the toroid
core (commonly a plastic or rubber tube) and connected along the first terminal. This allows
the coil to be open-ended, flexible, and able to be wrapped around a live conductor without
disturbing it.
It has an air core rather than an iron core. It has a low inductance and can respond to fast-
changing currents.
Because it has no iron core to saturate, it is highly linear even when subjected to large
currents, such as those used in electric power transmission or pulsed-power applications.
A correctly formed R-coil, with equally spaced windings, is largely immune to electromagnetic
interference.
i(t)
v(t)
A
r
10 k R3
330 k R1
10 nF C1
LF347
UI:A
1
GND
2
114
3
Vin
Vout
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 1777 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 1777 in the language / languages: English as an attachment in your email.

The manual is 3.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info